Strona 1 - DUAL 2722

® PowerCharger® DUAL 2722 Charger / Power Supply OWNER’S MANUAL

Strona 2

To Operate The DDM 1. Mount the battery to any position on the PowerCharger. When the PowerCharger has completed its communication with the batter

Strona 3 - FEATURES

“AUTOCAL” Feature When a DDM is installed in the PowerCharger, a special InterActive mode is automatically enabled for DIGITAL batteries placed on

Strona 4

OPERATION AS DC CAMERA SUPPLY FROM MAINS The DUAL 2722 can operate cameras and camcorders using the four pin camera output connector located on the

Strona 5 - Applications

FCC NOTICE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. T

Strona 6

LIMITED WARRANTY This three (3) year limited warranty for the battery product specified in this document (“Product”) is given by Anton/Bauer, Inc. (

Strona 7 - LED Indications

7595-0231 Rev G The power behind the best cameras capturing the best images in the world.sm The following are trademarks of Anton/Bauer,

Strona 8 - LCD Indications

TABLE OF CONTENTS INTRODUCTION…………………………………………………………………...1 FEATURES…………………………………………………………………………..1 SAFEGUARDS………………………………………………………………………2 GROUNDI

Strona 9

INTRODUCTION The DUAL 2722 is a simultaneous 2 position Interactive 2000 PowerCharger fast charger with 70 watt DC camera power supply. It incorpo

Strona 10 - To Operate The DDM

SAFEGUARDS Power Sources: This unit was designed to operate at mains voltages from 100 to 250 Volts AC, 50-60 Hz. Important: When powering a cha

Strona 11

Charging As with all Anton/Bauer chargers, charging with DUAL 2722 is fully automatic. Mount any Digital Logic Series or Logic Series battery to th

Strona 12

Three Stage Charging Methodology In general, the DUAL 2722 will deliver a three stage charge routine to each battery. 1. Stage One will deliver a h

Strona 13

LED Indications The DUAL 2722 has two sets of two LEDs (one red, one green) and one green status LED in the center. The green status LED indicates:

Strona 14 - LIMITED WARRANTY

1 - - - - - - - 2 - - - - - - - LCD Indications Each PowerCharger’s liquid crystal display (LCD) will display the status of each battery, as well

Strona 15

DDM (DIAGNOSTIC/DISCHARGE MODULE) A standard feature with the DUAL 2722, the DDM completes a battery management system, capable of testing battery